Stop electronic control downtime due to heat, dirt, and moisture! Cabinet Coolers maintain NEMA 4, 4X, and 12 integrity.

A low cost, reliable way to cool and purge electronic control panels. EXAIR Cabinet Coolers incorporate a vortex tube to produce cold air from compressed air - with no moving parts. The compact Cabinet Cooler can be installed in minutes through a standard electrical knockout. NEMA 12, 4, and 4X (IP54 and IP66) Cabinet Coolers that match the NEMA rating of the enclosure are available in many cooling capacities for large and small control panels.
Image

Why EXAIR Cabinet Cooler Systems?

The vortex tubes incorporated in the EXAIR Cabinet Coolers are constructed of stainless steel. Th e wear, corrosion and oxidation resistance of stainless steel assures long life and maintenance free operation. All Cabinet Coolers are UL Listed and CE compliant.

Applications

• Programmable controllers
• Line control cabinets
• Motor control centers
• Relay panels
• NC/CNC systems
• Modular control centers
• CCTV cameras
• Computer cabinets
• Laser housings
• Electronic scales
• Food service equipment

Advantages

• Low cost
• Compact
• Cooling capacities to 5,600 Btu/hr.(1,411 Kcal/hr.)
• Quiet
• Install in minutes
• Maintain NEMA 12, 4 and 4X integrity(IP54 and IP66)
• Stabilize enclosure temperatureand humidity
• No CFC’s
• No moving parts - maintenance free
• Mount in standard electrical knockout
•Stop nuisance tripping
• Stop heat damage
• Eliminate fans and fi lters
• Eliminate lost production
• Stop circuit drift
• Stop dirt contamination
• Provide washdown protection

Special Cabinet Coolers

•High temp. models for ambients up to 200°F (93°C) available
• Type 316 stainless steel available
• Purge models for non-hazardous locations available
Image

How The Cabinet Cooler Works

Compressed air enters the vortex tube powered Cabinet Cooler and is converted into two streams, one hot and one cold. Hot air from the vortex tube is muffled and exhausted through the vortex tube exhaust. The cold air is discharged into the control cabinet through the cold air distribution kit. The displaced hot air in the cabinet rises and exhausts to atmosphere through the cabinet air exhaust at a slight positive pressure. Thus, the control cabinet is both cooled and purged with cool, clean air. Outside air is never allowed to enter the control panel.

Environmental Considerations

NEMA 12 (IP54) Cabinet Coolers (dust-tight, oil-tight) are ideal for general industrial environments where no liquids or corrosives are present.
NEMA 4 (IP66) Cabinet Coolers (dust-tight, oil-tight, splash resistant, indoor/outdoor service) incorporate a low pressure relief valve for both the vortex tube and cabinet air exhaust. This valve closes and seals when the cooler is not operating to maintain the integrity of a NEMA 4 enclosure.
NEMA 4X (IP66) Cabinet Coolers offer the same protection as NEMA 4 but are constructed of stainless steel for food service and corrosive environments.