Cabinet Coolers

pdf Vivek Engineers - Cabinet Coolers Download Product PDF

Cabinet Cooler with Filter

Stop electronic control downtime due to heat, dirt and moisture!

UL listedCabinet Coolers maintain NEMA 12, 4 and 4X integrity and are

What are EXAIR Cabinet Coolers?

EXAIR’s cabinet coolers for control panels are UL Component Recognized and provide a low cost method of both purging and cooling electrical and electronic control panels. There are virtually no moving parts. These units are compact and can be installed in minutes through a standard electrical knockout. These units are available for NEMA Type 12, NEMA Type 4-4X rated panels. These user friendly air conditioning systems provide maintenance free cooling for a lifetime of protection without wearing out.

Why EXAIR Cabinet Coolers?

NEMA 4 Cabinet Cooler keeps inside cool and dry
A Model 4830 NEMA 4 Cabinet Cooler cools a panel with 20°F (-7°C) air while keeping the inside dry.

The cabinet cooler uses a stainless steel vortex tube to create cold air from ordinary compressed air.There are Three (3) Types to choose from:

1. Cabinet Panel Coolers NEMA Type 12 For Electronic Control Panels for General use in industrial environments where no direct liquid spray is applied to the unit. Stainless steel construction to hold up in corrosive environments.

2. Panel Coolers NEMA Type 4-4X For Electronic Control Panels - splash resistant, for use in wash down environments as well as outdoor use. Unique patent pending design for secure water tight protection. Stainless steel for food service and corrosive environments. Stainless steel also provides for long life in wet environments and for outdoor use.

Cabinet Coolers are compact

Cabinet Coolers are compact like this Model 4608 NEMA 4 measuring only 5" (127mm) high.

 

 

 

 

 

 

 

 

  • Programmable controllers
  • Line control cabinets
  • Motor control centers
  • Relay panels
  • NC/CNC systems
  • Modular control centers
  • CCTV cameras
  • Computer cabinets
  • Cool laser housings
  • Electronics scales
  • Food service equipment
  • Compact
  • Quiet - less than 75 dBA
  • Install in minutes
  • Maintain NEMA 4, 4X and 12 integrity (IP52 and 56)
  • Stabilize enclosure temperature and humidity
  • No CFC's
  • No moving parts - maintenance free
  • Mount in standard electrical knockout
  • Stop nuisance tripping
  • Stop heat damage
  • Eliminate fans and filters
  • Eliminate lost production
  • Stop circuit drift
  • Stop dirt contamination
  • Provide washdown protection
  • Low Cost

 

Special Cabinet Coolers

  • High temp. models for ambients up to 200°F (93°C) available
  • Type 316 stainless steel available
  • Purge models for non-hazardous locations available

 ccwrksdiagram Vivek Engineers - Cabinet CoolersCompressed air enters the vortex tube powered Cabinet Cooler and is converted into two streams, one hot and one cold. (For more information on vortex tube operation, see Vortex Tubes.) Hot air from the vortex tube is muffled and exhausted through the vortex tube exhaust. The cold air is discharged into the control cabinet through the cold air distribution kit. The displaced hot air in the cabinet rises and exhausts to atmosphere through the cabinet air exhaust at a slight positive pressure. Thus, the control cabinet is both cooled and purged with cool, clean air. Outside air is never allowed to enter the control panel.

EXAIR Cabinet Coolers are available with or without thermostat control. The continuous coolers (Model 4200 and 4700 series) are recommended when constant cooling and a constant positive purge are desirable. The thermostatically controlled systems (Model 4300 and 4800 series) save air by activating the cooler only when internal temperatures approach critical levels. The adjustable thermostat is factory set at 95°F (35°C). Thermostatic systems are recommended where heat load fluctuates and continual purge is not required.

All EXAIR Cabinet Cooler Systems contain a 5 micron, Automatic Drain Filter for the compressed air supply and a Cold Air Distribution Kit to circulate the cold air throughout the enclosure. See below for more details.

Dangerous Fan Cooled Electrical Panel

A dangerous shock hazard exists when the panel door is opened to let a fan blow hot, dirty shop air at the electronics.

It happens when you least expect it. High temperatures can cook the electronics that control your machines, resulting in erroneous readings, trip-outs or fried circuit boards. Cooling the electrical cabinet can eliminate these problems, but how will you do it?

Heat Exchanger

 

Heat Exchangers and Pipes

These have serious limitations when it comes to summer time heat. In many cases, the temperature of the hot plant on a summer day is close to that inside the enclosure. There is not enough difference in temperature for a decent heat exchange.

 

Refrigerant Panel Air Conditioner

Refrigerant Panel Air Conditioners

These coolers are expensive, take almost a day to install, and are prone to failure when dust and dirt clogs the filter. Vibration from machinery contributes to component failures and loss of freon. Life expectancy for most compressors is rated at 2.5 years of continuous operation. Average replacement cost for a bad compressor is $750 plus installation. Often, a floor drain is not readily available for the condensation tube.

 

EXAIR Cabinet Cooler

EXAIR Cabinet Coolers

Our compressed air operated Cabinet Coolers are the low cost solution. NEMA 12, 4 and 4X models are available that are very compact and mount in just minutes through an ordinary electrical knockout. Thermostat control limits compressed air use by operating the Cabinet Cooler only when the temperature inside the enclosure reaches critical levels.

Heat exchangers, heat pipes and refrigerant coolers all have filters that can clog. Left unattended, mechanical failure of the cooler is likely. And, the expensive equipment in the electrical enclosure can malfunction, overheat and shut down the entire machine or process. EXAIR Cabinet Coolers have no moving parts to wear out and do not require constant monitoring. All models are UL Listed and available in a large number of styles and cooling capacities.

NEMA 12 (IP52) Cabinet Coolers (dust-tight, oil-tight) are ideal for general industrial environments where no liquids or corrosives are present.

NEMA 4 (IP56) Cabinet Coolers (dust-tight, oil-tight, splash resistant, indoor/outdoor service) incorporate a low pressure relief valve for both the vortex tube and cabinet air exhaust. This valve closes and seals when the cooler is not operating, to maintain the integrity of a NEMA 4 enclosure.

NEMA 4X (IP56) Cabinet Coolers offer the same protection as NEMA 4 but are constructed of stainless steel for food service and corrosive environments.

Special Cabinet Coolers

EXAIR manufactures special NEMA 4, 4X and 12 Cabinet Coolers suited to specific environmental requirements.

High Temperature Cabinet Cooler

High Temperature Cabinet Coolers (shown top right) for ambients of 125° to 200°F (52° to 93°C) are available. Internal components can withstand high temperatures (like those near furnaces, ovens, etc.).

Non-Hazardous Purge Cabinet Cooler

The Non-Hazardous Purge Cabinet Cooler Systems (shown middle right) are ideal for dirty areas where contaminants might normally pass through small holes or conduits. Under normal conditions, the NHP Cabinet Cooler Systems provide a slight positive pressure in the enclosure by passing 1 SCFM (28 SLPM) of air through the cooler, when the solenoid valve is in the closed position. When the thermostat detects high temperature, it energizes the solenoid valve to pass full line pressure to the Cabinet Cooler, giving it full cooling capability.

Type 316 Stainless Steel NEMA 4X Cabinet Cooler

Type 316 Stainless Steel NEMA 4X Cabinet Coolers (shown bottom right) are suitable for food service, pharmaceutical, harsh and corrosive environments, and other applications where 316SS is preferred. Capacities from 650 to 2800 Btu/hr. (164 to 706 Kcal/hr.) are available.

 

 

 

dualcc200 Vivek Engineers - Cabinet Coolers

EXAIR's Dual Cabinet Cooler Systems are ideal for large electrical enclosures and high heat loads. Dual Cabinet Coolers are available with cooling capacities of 4,000, 4,800 and 5,600 Btu/hr. Dual Cabinet Cooler Systems are available in NEMA 12, 4, and 4X models. For more information, contact your distributor.

 

 

 

Cold Air Distribution Kit

Cold Air Distribution Kit: The kit includes a length of flexible vinyl tubing used to direct the cold air for circulation, or to hot spots. Tubing connectors and adhesive backed clips to hold the tubing in place are provided.

Filtration: EXAIR Cabinet Cooler Systems include a 5 micron automatic drain water and dirt filter. This filter is critical for protection of electronics from water in the compressed air line. If oil is present in the compressed air, a coalescing (oil removal) filter, such as EXAlR Model 9005 is recommended.

Humidity: For a continuous operating Cabinet Cooler, relative humidity inside the enclosure stabilizes at 45%. No moisture condenses inside the enclosure. (The enclosure must be sealed to prevent condensation.)

Inlet Air Temperature: Cabinet Cooler Systems provide a 50°F (28°C) temperature drop from supply air temperature when the inlet pressure is 80 PSIG (5.5 BAR). Elevated inlet temperature will produce a corresponding rise in cold air temperature and reduction in cooling capacity. Low air pressures will also reduce the cooling capacity.

Mounting: The Cabinet Cooler mounts to the enclosure through a drilled hole or electrical knockout. The NEMA 12 Cabinet Coolers may be mounted on the top or side of the panel. NEMA 4 and 4X Cabinet Coolers must be mounted on the top of the panel, or on the side of the panel using our new side mount kits.

Solenoid Valve and Thermostat: Cabinet Cooler Systems with thermostat control include a solenoid valve and thermostat that limit the flow of compressed air to only when cooling is needed. The solenoid valve is rated 120V, 60 Hz or 110V, 50 Hz. It is UL Listed, CSA Certified.

The thermostat is factory set at 95°F (35°C). It will normally hold ±2°F (1°C) inside the cabinet. It is rated 120V, 50/60 Hz and is UL Recognized, CSA Certified.

Continuous Operation Cabinet Cooler Kit

Systems for continuous operation include a Cabinet Cooler, cold air distribution kit and filter.

Solenoid and Thermostat Control Cabinet Cooler Kit

Solenoid Valve and Thermostat.

Thermostat Control Cabinet Cooler Kit

Systems with thermostat control include a Cabinet Cooler, thermostat, solenoid valve, cold air distribution kit and filter.

UL LogoUL-REC1 Vivek Engineers - Cabinet CoolersCSAMARK1 Vivek Engineers - Cabinet Coolers

 

ETC

EXAIR’s ETC (Electronic Temperature Control) delivers precise temperature control for your enclosure. Temperature is maintained with an accuracy of ±1°F of the dial setting. The digital readout monitors the internal temperature of the electrical enclosure and activates the solenoid valve (included) only when the temperature setting is exceeded. The ABS/PC plastic enclosure of the ETC is suitable for NEMA 12, 4 and 4X environments. (Cabinet Cooler not included.)

 

Side Mount Cabinet Cooler

EXAIR’s new Side Mount Kits make mounting on the side of an electrical enclosure possible when there is limited space on the top or side. (NEMA 4 and 4X Cabinet Coolers must be mounted vertically.) The Side Mount Kits maintain the NEMA rating of large and small NEMA Type 12, 4 and 4X enclosures. They mount in a standard electrical knockout (1-1/2 NPS). Side Mount Kits for NEMA 12 Cabinet Coolers have an aluminum construction. Those for NEMA 4 and 4X Cabinet Coolers are Type 303 stainless steel.

The Side Mount Kits are suitable for use on large or small electrical enclosures with Cabinet Coolers that have cooling capacities up to 2800 Btu/hr.

Contact us to purchase these Side Mount Cabinet Cooler Kits.

Side Mount Kits
Model # Description
4909
Side Mount Kit for NEMA 12 Cabinet Coolers up to
550 Btu/hr. (139 Kcal/hr.)
4910
Side Mount Kit for NEMA 12 Cabinet Coolers,
650 Btu/hr. (165 Kcal/hr.) and higher
4906
Side Mount Kit for NEMA 4 and 4X Cabinet Coolers up to 550 Btu/hr. (139 Kcal/hr.)
4907
Side Mount Kit for NEMA 4 and 4X Cabinet Coolers,
650 Btu/hr. (165 Kcal/hr.) and higher

90 Degree Side Mount Dimensions

90 Degree Side Mount Kit Dimensions
Model UOM A B C D E F G
4906 in 2.50 2.50 1.50 3.50 3.03 1 NPS 1-1/2 NPS
mm 64 64 38 89 77
4907 in 2.50 2.50 1.50 3.50 3.03 1-1/2 NPS 1-1/2 NPS
mm 64 64 38 89 77
4909 in 2.50 2.50 1.50 2.19 1.73 1/2 NPS 1-1/2 NPS
mm 64 64 38 56 44
4910 in 2.50 2.50 1.50 3.50 3.03 3/4 NPS 1-1/2 NPS
mm 64 64 38 89 77

 

BSP Threads Available - Contact Us


Click a product to expand its model tables {slider=NEMA 12 Models}
NEMA 12 Cabinet Cooler Only
Model #
Description
4008
NEMA 12 Cabinet Cooler Only, 550 Btu/hr. (139 Kcal/hr.), 1/8 NPT
4015
NEMA 12 Cabinet Cooler Only, 1000 Btu/hr. (252 Kcal/hr.), 1/4 NPT
4025
NEMA 12 Cabinet Cooler Only, 1700 Btu/hr. (428 Kcal/hr.), 1/4 NPT
4030
NEMA 12 Cabinet Cooler Only, 2000 Btu/hr. (504 Kcal/hr.), 1/4 NPT
4040
NEMA 12 Cabinet Cooler Only, 2800 Btu/hr. (706 Kcal/hr.), 1/4 NPT
NEMA 12 Continuous Operation Cabinet Cooler Systems
Model #
Description
4208J
Cabinet Cooler System, Continuous Operation, 550 Btu/hr. (139 Kcal/hr.)
4215J
Cabinet Cooler System, Continuous Operation, 1000 Btu/hr. (252 Kcal/hr.)
4225J
Cabinet Cooler System, Continuous Operation, 1700 Btu/hr. (428 Kcal/hr.)
4230J
Cabinet Cooler System, Continuous Operation, 2000 Btu/hr. (504 Kcal/hr.)
4240J
Cabinet Cooler System, Continuous Operation, 2800 Btu/hr. (706 Kcal/hr.)
4250J
Dual Cabinet Cooler System, Continuous Operation, 3400 Btu/hr. (857 Kcal/hr.)
4260J
Dual Cabinet Cooler System, Continuous Operation, 4000 Btu/hr. (1008 Kcal/hr.)
4270J
Dual Cabinet Cooler System, Continuous Operation, 4800 Btu/hr. (1210 Kcal/hr.)
4280J
Dual Cabinet Cooler System, Continuous Operation, 5600 Btu/hr. (1411 Kcal/hr.)
Continuous Operation Systems include the NEMA 12 Cabinet Cooler(s) and cold air distribution kit.
NEMA 12 Thermostat Control Cabinet Cooler Systems
Model #
Description
4308J-240
Cabinet Cooler System, Thermostat Control, 550 Btu/hr. (139 Kcal/hr.)
4315J-240
Cabinet Cooler System, Thermostat Control, 1000 Btu/hr. (252 Kcal/hr.)
4325J-240
Cabinet Cooler System, Thermostat Control, 1700 Btu/hr. (428 Kcal/hr.)
4330J-240
Cabinet Cooler System, Thermostat Control, 2000 Btu/hr. (504 Kcal/hr.)
4340J-240
Cabinet Cooler System, Thermostat Control, 2800 Btu/hr. (706 Kcal/hr.)
4350J-240
Dual Cabinet Cooler System, Thermostat Control, 3400 Btu/hr. (857 Kcal/hr.)
4360J-240
Dual Cabinet Cooler System, Thermostat Control, 4000 Btu/hr. (1008 Kcal/hr.)
4370J-240
Dual Cabinet Cooler System, Thermostat Control, 4800 Btu/hr. (1210 Kcal/hr.)
4380J-240
Dual Cabinet Cooler System, Thermostat Control, 5600 Btu/hr. (1411 Kcal/hr.)
Thermostat Control Systems include the NEMA 12 Cabinet Cooler(s), cold air distribution kit, solenoid valve and thermostat.
NEMA 12 Electronic Temperature Control Cabinet Cooler Systems
Model #
Description
4308J-ETC240
Cabinet Cooler System, 240V ETC, 550 Btu/hr. (139 Kcal/hr.)
4315J-ETC240
Cabinet Cooler System, 240V ETC, 1000 Btu/hr. (252 Kcal/hr.)
4325J-ETC240
Cabinet Cooler System, 240V ETC, 1700 Btu/hr. (428 Kcal/hr.)
4330J-ETC240
Cabinet Cooler System, 240V ETC, 2000 Btu/hr. (504 Kcal/hr.)
4340J-ETC240
Cabinet Cooler System, 240V ETC, 2800 Btu/hr. (706 Kcal/hr.)
4350J-ETC240
Dual Cabinet Cooler System, 240V ETC, 3400 Btu/hr. (857 Kcal/hr.)
4360J-ETC240
Dual Cabinet Cooler System, 240V ETC, 4000 Btu/hr. (1008 Kcal/hr.)
4370J-ETC240
Dual Cabinet Cooler System, 240V ETC, 4800 Btu/hr. (1210 Kcal/hr.)
4380J-ETC240
Dual Cabinet Cooler System, 240V ETC, 5600 Btu/hr. (1411 Kcal/hr.)
ETC-Electronic Temperature Control Systems include the NEMA 12 Cabinet Cooler(s), cold air distribution kit and Electronic Temperature Control.

NEMA 4 Cabinet Cooler Only
Model #
Description
4608
NEMA 4 Cabinet Cooler Only, 550 Btu/hr. (139 Kcal/hr.)
4615
NEMA 4 Cabinet Cooler Only, 100 Btu/hr. (252 Kcal/hr.)
4625
NEMA 4 Cabinet Cooler Only, 1700 Btu/hr. (428 Kcal/hr.)
4630
NEMA 4 Cabinet Cooler Only, 2000 Btu/hr. (504 Kcal/hr.)
4640
NEMA 4 Cabinet Cooler Only, 2800 Btu/hr. (706 Kcal/hr.)
NEMA 4 Continuous Operation Cabinet Cooler Systems
Model #
Description
4708J
Cabinet Cooler System, Continuous Operation, 550 Btu/hr. (139 Kcal/hr.)
4715J
Cabinet Cooler System, Continuous Operation, 1000 Btu/hr. (252 Kcal/hr.)
4725J
Cabinet Cooler System, Continuous Operation, 1700 Btu/hr. (428 Kcal/hr.)
4730J
Cabinet Cooler System, Continuous Operation, 2000 Btu/hr. (504 Kcal/hr.)
4740J
Cabinet Cooler System, Continuous Operation, 2800 Btu/hr. (706 Kcal/hr.)
4750J
Dual Cabinet Cooler System, Continuous Operation, 3400 Btu/hr. (857 Kcal/hr.)
4760J
Dual Cabinet Cooler System, Continuous Operation, 4000 Btu/hr. (1008 Kcal/hr.)
4770J
Dual Cabinet Cooler System, Continuous Operation, 4800 Btu/hr. (1210 Kcal/hr.)
4780J
Dual Cabinet Cooler System, Continuous Operation, 5600 Btu/hr. (1411 Kcal/hr.)
Continuous Operation Systems include the NEMA 4 Cabinet Cooler(s) and cold air distribution kit.
NEMA 4 Thermostat Control Cabinet Cooler Systems
Model #
Description
4808J-240
Cabinet Cooler System, Thermostat Control, 550 Btu/hr. (139 Kcal/hr.)
4815J-240
Cabinet Cooler System, Thermostat Control, 1000 Btu/hr. (252 Kcal/hr.)
4825J-240
Cabinet Cooler System, Thermostat Control, 1700 Btu/hr. (428 Kcal/hr.)
4830J-240
Cabinet Cooler System, Thermostat Control, 2000 Btu/hr. (504 Kcal/hr.)
4840J-240
Cabinet Cooler System, Thermostat Control, 2800 Btu/hr. (706 Kcal/hr.)
4850J-240
Dual Cabinet Cooler System, Thermostat Control, 3400 Btu/hr. (857 Kcal/hr.)
4860J-240
Dual Cabinet Cooler System, Thermostat Control, 4000 Btu/hr. (1008 Kcal/hr.)
4870J-240
Dual Cabinet Cooler System, Thermostat Control, 4800 Btu/hr. (1210 Kcal/hr.)
4880J-240
Dual Cabinet Cooler System, Thermostat Control, 5600 Btu/hr. (1411 Kcal/hr.)
Thermostat Control Systems include the NEMA 4 Cabinet Cooler(s), cold air distribution kit, NEMA 4/4X solenoid valve and thermostat.
NEMA 4 Electronic Temperature Control Cabinet Cooler Systems
Model #
Description
4808J-ETC240
Cabinet Cooler System, 240V ETC, 550 Btu/hr. (139 Kcal/hr.)
4815J-ETC240
Cabinet Cooler System, 240V ETC, 1000 Btu/hr. (252 Kcal/hr.)
4825J-ETC240
Cabinet Cooler System, 240V ETC, 1700 Btu/hr. (428 Kcal/hr.)
4830J-ETC240
Cabinet Cooler System, 240V ETC, 2000 Btu/hr. (504 Kcal/hr.)
4840J-ETC240
Cabinet Cooler System, 240V ETC, 2800 Btu/hr. (706 Kcal/hr.)
4850J-ETC240
Dual Cabinet Cooler System, 240V ETC, 3400 Btu/hr. (857 Kcal/hr.)
4860J-ETC240
Dual Cabinet Cooler System, 240V ETC, 4000 Btu/hr. (1008 Kcal/hr.)
4870J-ETC240
Dual Cabinet Cooler System, 240V ETC, 4800 Btu/hr. (1210 Kcal/hr.)
4880J-ETC240
Dual Cabinet Cooler System, 240V ETC, 5600 Btu/hr. (1411 Kcal/hr.)
ETC-Electronic Temperature Control Systems include the NEMA 4 Cabinet Cooler(s), cold air distribution kit and Electronic Temperature Control.

NEMA 4X Cabinet Cooler Only
Model #
Description
4608SS
NEMA 4X Cabinet Cooler Only, 550 Btu/hr. (139 Kcal/hr.)
4615SS
NEMA 4X Cabinet Cooler Only, 1000 Btu/hr. (252 Kcal/hr.)
4625SS
NEMA 4X Cabinet Cooler Only, 1700 Btu/hr. (428 Kcal/hr.)
4630SS
NEMA 4X Cabinet Cooler Only, 2000 Btu/hr. (504 Kcal/hr.)
4640SS
NEMA 4X Cabinet Cooler Only, 2800 Btu/hr. (706 Kcal/hr.)
NEMA 4X Continuous Operation Cabinet Cooler Systems
Model #
Description
4708SSJ
Cabinet Cooler System, Continuous Operation, 550 Btu/hr. (139 Kcal/hr.)
4715SSJ
Cabinet Cooler System, Continuous Operation, 1000 Btu/hr. (252 Kcal/hr.)
4725SSJ
Cabinet Cooler System, Continuous Operation, 1700 Btu/hr. (428 Kcal/hr.)
4730SSJ
Cabinet Cooler System, Continuous Operation, 2000 Btu/hr. (504 Kcal/hr.)
4740SSJ
Cabinet Cooler System, Continuous Operation, 2800 Btu/hr. (706 Kcal/hr.)
4750SSJ
Dual Cabinet Cooler System, Continuous Operation, 3400 Btu/hr. (857 Kcal/hr.)
4760SSJ
Dual Cabinet Cooler System, Continuous Operation, 4000 Btu/hr. (1008 Kcal/hr.)
4770SSJ
Dual Cabinet Cooler System, Continuous Operation, 4800 Btu/hr. (1210 Kcal/hr.)
4780SSJ
Dual Cabinet Cooler System, Continuous Operation, 5600 Btu/hr. (1411 Kcal/hr.)
Continuous Operation Systems include the NEMA 4X Cabinet Cooler(s); and cold air distribution kit.
NEMA 4X Thermostat Control Cabinet Cooler Systems
Model #
Description
4808SSJ-240
Cabinet Cooler System, Thermostat Control, 550 Btu/hr. (139 Kcal/hr.)
4815SSJ-240
Cabinet Cooler System, Thermostat Control, 1000 Btu/hr. (252Kcal/hr.)
4825SSJ-240
Cabinet Cooler System, Thermostat Control, 1700 Btu/hr. (428 Kcal/hr.)
4830SSJ-240
Cabinet Cooler System, Thermostat Control, 2000 Btu/hr. (504 Kcal/hr.)
4840SSJ-240
Cabinet Cooler System, Thermostat Control, 2800 Btu/hr. (706 Kcal/hr.)
4850SSJ-240
Dual Cabinet Cooler System, Thermostat Control, 3400 Btu/hr. (857 Kcal/hr.)
4860SSJ-240
Dual Cabinet Cooler System, Thermostat Control, 4000 Btu/hr. (1008 Kcal/hr.)
4870SSJ-240
Dual Cabinet Cooler System, Thermostat Control, 4800 Btu/hr. (1210 Kcal/hr.)
4880SSJ-240
Dual Cabinet Cooler System, Thermostat Control, 5600 Btu/hr. (1411 Kcal/hr.)
Thermostat Control Systems include the NEMA 4X Cabinet Cooler(s), cold air distribution kit, NEMA 4/4X solenoid valve and thermostat.
NEMA 4X Electronic Temperature Control Cabinet Cooler Systems
Model #
Description
4808SSJ-ETC240
Cabinet Cooler System, 240V ETC, 550 Btu/hr. (139 Kcal/hr.)
4815SSJ-ETC240
Cabinet Cooler System, 240V ETC, 1000 Btu/hr. (252 Kcal/hr.)
4825SSJ-ETC240
Cabinet Cooler System, 240V ETC, 1700 Btu/hr. (428 Kcal/hr.)
4830SSJ-ETC240
Cabinet Cooler System, 240V ETC, 2000 Btu/hr. (504 Kcal/hr.)
4840SSJ-ETC240
Cabinet Cooler System, 240V ETC, 2800 Btu/hr. (706 Kcal/hr.)
4850SSJ-ETC240
Dual Cabinet Cooler System, 240V ETC, 3400 Btu/hr. (857 Kcal/hr.)
4860SSJ-ETC240
Dual Cabinet Cooler System, 240V ETC, 4000 Btu/hr. (1008 Kcal/hr.)
4870SSJ-ETC240
Dual Cabinet Cooler System, 240V ETC, 4800 Btu/hr. (1210 Kcal/hr.)
4880SSJ-ETC240
Dual Cabinet Cooler System, 240V ETC, 5600 Btu/hr. (1411 Kcal/hr.)
ETC-Electronic Temperature Control Systems include the NEMA 4X Cabinet Cooler(s), cold air distribution kit and Electronic Temperature Control.

Accessories
Model #
Description
4906
Side Mount Kit for NEMA 4 and 4X Cabinet Coolers up to 550 Btu/hr. (139 Kcal/hr.)
4907
Side Mount Kit for NEMA 4 and 4X Cabinet Coolers, 650 Btu/hr. (165 Kcal/hr.) and higher
4909
Side Mount Kit for NEMA 12 Cabinet Coolers up to 550 Btu/hr. (139 Kcal/hr.)
4910
Side Mount Kit for NEMA 12 Cabinet Coolers, 650 Btu/hr. (165 Kcal/hr.) and higher
4902
Cold Muffler only
4904
Cold Air Distribution Kit (for all Cabinet Coolers except 550 Btu/hr. output)
4905
Cold Air Distribution Kit (for Cabinet Coolers with 550 Btu/hr. output only)
9017
Thermostat Only
9018
NEMA 4-4X Solenoid Valve, 120V, 50/60 Hz, 1/4 NPT, 40 SCFM (1133 SLPM)
9020
Solenoid Valve Only, 120V, 50/60 Hz, 1/4 NPT, 40 SCFM (1133 SLPM)
9021
Solenoid Valve Only, 200-240V, 50/60 Hz, 1/4 NPT, 40 SCFM (1133 SLPM)
9024
NEMA 4-4X Solenoid Valve Only, 200-240V, 50-60Hz, 1/4 NPT, 40 SCFM (1133 SLPM)

Valves/Thermostats

Valves and Thermostat Kits
Model #
Description
9015
Valve and Thermostat Kit - 120V
9016
NEMA 4-4X Valve and Thermostat Kit
9044
Valve and Thermostat Kit - 200-240V
9045
NEMA 4-4X Valve and Thermostat Kit - 200-240V

ETC